PCM 1 PAIR SCREENED INTRAOFFICE CABLE
each pair with Individual Shield and Water Blocking Tape and Individual Drain Wire
Cable Structure
1, Conductor is made of solid wire of plain annealed high conductivity copper
Nominal Diameter: 0.5 mm Tolerance: +10%
2, Insulation made of Polyethylene complying to BS 6234
Nominal Thickness: 0.15 mm Tolerance: +/-10%
2 insulated conductors twisted together with a lay length no longer than 50 mm.
3, Non-hygroscopic tape surrounding one pair of insulated conductor.
Nominal Thickness: 0.025 mm Tolerance: +10%
4, Drain wire made of tinned annealed copper conductor
Diameter: 0.5 mm Tolerance: +10%
5, Screen made of Aluminium Mylar tape
Nominal Thickness: 0.05 mm Tolerance: -10%
6, Outer jacket made of Low Smoke Zero Halogen compound in grey / orange
Diameter: 0.5 mm Tolerance: +10%
Electrical Characteristics:
Dielectric Strength 1 kV rms at 50 Hz for 1 full minute without breakdown
Conductor Resistance less than 95 ohms/km at 20°C
Insulation Resistance Not less than 5 Gigaohms-km at 500 Vdc for 1 full minute
Mutual Capacitance 75 nF/km maximum at 1 kHz
Characteristic Impedance 100 ohms +/- 20% measured between 772 kHz and 3156 kHz
Maximum Attenuation 2.5 dB at 360 kHz 4.0 dB at 772 kHz
per 100 meter 7.5 dB at 3156 kHz
Equal Level Far-end Better than 85 dB/15 meter (10 kHz – 1 MHz)
Crosstalk Attenuation The value of equal level far-end crosstalk attenuation over 85 dB
at a resistance 110 ohms between 10 kHz and 1.0 MHz.