INTERNAL , NON-METALLIC OPTICAL FIBRE CABLE
WITH FLAME RETARDING SHEATH FOR CUSTOMER PREMISES
Test Item | Figures | Test Method |
Cable Tensile Strength | 4 core fiber cable equal or greater than 1000N | IEC 60794-1-E1 |
8 core fiber cable equal or greater than 1000N | ||
12 to 24 core fiber cable equal or greater than 2500N | ||
Cable Impact Test | 10Nm | IEC 60794-1-E4 |
Cable Crush Test | 2000N | IEC 60794-1-E3 |
Minimum Cable Bending Radius | ||
Static | Diameter of cable x 10 times or below | |
Dynamic | Diameter of cable x 15 times or below | |
Proof Test Level | 1% | |
Maximum Cable Pulling Tension | The maximum pulling tension for various fiber cable | |
4 core | 600 lbF (2,700 Newtons) | |
8 core | 650 lbF (2,700 Newtons) | |
12 to 24 core | 750 lbF (2,700 Newtons) |
Jacket Material | Polyvinyl Chloride Or The Low Smoke Zero Halogen jacket | ||||||
For Low Smoke Zero Halogen type, the jacket shall be tested to and comply with ASTMR 162 – Flame | |||||||
Spread Index, ASTMR E662 – Smoke Density Generation and | |||||||
Bombardier SMP-800C – Toxic Gas Generation. | |||||||
Number of fibres | 4 | 6 | 8 | 12 | 24 | 48 | |
Cable diameter* | 5 mm | 5.5 mm | 6 mm | 6.5 mm | 8.5 mm | 13 mm | |
Maximum cable weight | 50 kg/km | 50 kg/km | 50 kg/km | 60 kg/km | 65 kg/km | 120 kg/km | |
Minimum bending radius | |||||||
Long term | 100 mm | 100 mm | 100 mm | 130 mm | 230 mm | 250 mm | |
Short term | 50 mm | 50 mm | 50 mm | 75 mm | 115 mm | 120 mm | |
Temperature range | |||||||
Operation and installation | -10゚C to +55 ゚C -20゚C to +70 ゚C |
||||||
Part Number | |||||||
Om3 | SG004OT | SG006OT | SG008OT | SG012OT | SG024OT | SG048OT | |
Om4 | SG004OF | SG006OF | SG008OF | SG012OF | SG024OF | SG048OF | |
50/125um | SG004MS | SG006MS | SG008MS | SG012MS | SG024MS | SG048MS | |
62.5/125um | SG004MB | SG006MB | SG008MB | SG012MB | SG024MB | SG048MB | |
8.3/125um | SG004SB | SG006SB | SG008SB | SG012SB | SG024SB | SG048SB |