Showing all 12 results

  • 2 WIRE JUMPER PVC/NYLON

    CROSS LINKED PVC/NYLON INSULATED WIRE

    1 pair with 0.5 mm Annealed Copper Conductor

  • 8723 2 pair shield LSZH control cable

    CONTROL CABLE – TINNED WIRE, TWO PAIR, 7 X AWG30, LSZH

    Item Number: SG-8723

    1) Conductor: Size :22AWG  Tinned copper conductor to BS4109

    2) Insulator: PE insulation  Minimum Insulation Diameter: 1.3mm+/-5%

    3) Individual Shield: 100% shield coverage (aluminum-polyester foil)

    4) Ground Wire: 24AWG stranded tinned copper drain wire

    5) Jacket Material: low smoke zero halogen compound

    External Diameter: 5 mm +/-5%

  • 8760 1 pair shield control cable

    8760 1 pair shield control cable

    Part Number: SG-8760

    Application:

    Security Systems

    Intercom / PA Systems

    Sound/Audio Systems

    Power-Limited Controls

    Construction:

    1) Conductor: Tinned copper wires,AWG18 stranded 16*0.25mm

    2) Insulator: PE, Twisted Pair Color: White / Black

    3) Overall Shield: Aluminium Foil 100% coverage

    4) Drain wire: Tinned copper wires, AWG22 stranded 7*0.25mm

    5) Jacket: PVC ( grey color )

  • 8761 1 pair shield control cable

    8761 1 pair shield control cable

    Part Number: SG-8761

    Application:

    Security Systems

    Intercom / PA Systems

    Sound/Audio Systems

    Power-Limited Controls

    Construction:

    1) Conductor: Tinned copper wires,AWG22 stranded 7*0.25mm

    2) Insulator: PE, Twisted Pair Color: White / Black

    3) Overall Shield: Aluminium Foil 100% coverage

    4) Drain wire: Tinned copper wires, AWG22 stranded 7*0.25mm

    5) Jacket: PVC ( grey color )

  • CAT 5E 25 Pair UTP Cable

    Item Number: SG-CE25

    This cable meets or exceeds the requirements of ANSI/TIA-568-C.2

    Category 5E Cable Tested to 500 MHz

  • CAT 6 UTP AWG23 × 4 Pair Cable

    Item Number: S695

    This cable meets or exceeds the requirements of TIA/EIA-568.2-1, IEC 11801

    Category 6 Cable Tested to 500 MHz

  • DSLAM Line Cable – 24 ports

    Application: One end is connected to the PSTN or LINE port of the SPL board., the PSTN or xDSL port of the service board. Another end is connected to the main distribution frame (MDF).

  • Outdoor armour 27 x 2.5mm sq screen control cable

    Item Number:SG 270C

    Fire Resistance – IEC 60332-3 / EN 50266

    Smoke Emission – IEC 61034 / EN 50268

    Corrosive and Acid Gas Emission – IEC 60754 / EN 50267-2-2

  • Outdoor Screen Control Cable, 6 pair, Individual shield + Overall shield with steel tape armor

    Outdoor Screen Control Cable, 6 pair, Individual shield + Overall shield with steel tape armor

    Part Number: SG-803

  • Outdoor Steel Tape Armor Cat 6 UTP cable with Dual LSOH jacket

    Item Number: SG6FA

    Application: Installing in cable duct / rigid and flexible conducit / junction gateway

    This cable meets or exceeds the requirements of IEC 11801 Class D

     

  • PCM 1 PAIR SCREENED INTRAOFFICE CABLE

    PCM 1 PAIR SCREENED INTRAOFFICE CABLE
    each pair with Individual Shield and Water Blocking Tape and Individual Drain Wire

  • PROFIBUS DP Basic LSHF Cable

    ICS PB DP BASIC 1x2xAWG22 LSHF

    Part Number: SG-DP-B2

    Standards:

    EN 50170 part 8-2, cable type A, IEC 61158 and IEC 61784

    LSHF: IEC 60332-1, IEC 61034-2, IEC 60754-1/2

    LSHF-FR: IEC 60332-3-24, IEC 61034-2, IEC 60754-1/2